High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection

Product Details
Customization: Available
Theory: Pneumatic
Type: PTC Hot Combination Disinfection
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 16 foreign trading staff(s) and 15 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (32)
  • High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
  • High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
  • High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
  • High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
  • High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
  • High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
Find Similar Products

Basic Info.

Model NO.
HTY-8 cube
Certification
CE, FDA
Electric Tension
380V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Transport Package
Wooden Case or Suitable Transportation
Specification
5200*1200*1300
Trademark
ANGEL
Origin
Henan
Production Capacity
50sets/Month

Product Description

Company Introduction
High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection

The Group relies on aggregating professionals in the field of medical equipment, concentrated technical forces to invest in research and development, and rapidly rises in the medical field. With great investment in research and development and innovation, the company has achieved a series of results in the related fields of ethylene oxide sterilizers. Combined with the 5G intelligent AI platform to realize the intelligent operation of the equipment, the simplicity, safety, and sterilization effect exceed the customer's requirements. We always treat our customers with a high standard and a responsible attitude. The corporate philosophy of being a person first, and then acting, has laid a solid foundation for the group company to deepen its cultivation in the medical device industry.


High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection

Technical Description of Ethylene Oxide Sterilizer

Air replacement
Automatic ventilation, air exchange frequency and interval can be set freely
Automatic control system
One-click start to end, the whole process is automatically completed with print record
Display status
Display temperature, humidity, pressure, sterilization time, residual gas treatment time, number of times
Printer
The whole process of sterilization information record printing, in order to verify the check.
Humidity sensor
The built-in humidity sensor automatically detects the humidity in the cavity to ensure that the humidity in the cavity is not lower than 45% RH.
Pressure sensor
The inner pressure sensor automatically detects the pressure inside the cavity to ensure the accuracy and efficiency of the pressure.
Temperature sensor
The built-in temperature sensor automatically detects the cavity temperature to ensure that the cavity temperature remains within the accurate range of 50 ºC ±3 ºC.
Humidifying system
Pulse humidification in the vacuum state ensures that the humidity in the cavity is uniform and controllable, and the humidity of the sterilizing chamber should be controlled within the range of 45- 80% relative humidity.
Residual gas treatment unit
Filtration efficiency of filter for particle diameter ≥ 0.3 μ m,not less than 99.5%.
[Sterilization chamber leakage rate
The leakage rate is measured under the condition of no-load and sterilization room temperature, the
test pressure is -50kPa, and the measurement time is 1h.
[Vacuum rate]
Under no-load conditions, the time for the disinfection cabinet to reach -60kPa from normal
pressure should be ≤30min.
[Vacuum system]
The oil-free vacuum pump is used, which is simple and convenient, the vacuum rate is fast, and the
service life is long.
[Heating system]
It adopts explosion-proof electric heating device, which is more convenient and quick.

[Tray rack] Use 304 stainless steel tray rack.

[Sterilization chamber leakage rate]
With over-voltage and over-temperature protection function, it is more safe and reliable.

[Casters] Yes.

[Alarm system] 
There is a high temperature alarm system and an ultra-low pressure alarm system; when the
disinfection temperature of the disinfection room exceeds 59 ° C, it should be able to sound an
alarm.

[Category] Class II medical instruments.

Parameters of different models Ethylene Oxide Sterilizers
High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection

 
Model HTY-2cube HTY-3cube HTY-6cube
Disinfection mode Low temperature Low temperature Low temperature
Rated power 6KW 14KW 14KW
Liner specifications
L * W * H (mm)
2400*900*1100 2000×1000×1500 3350*1200*1500
Liner specifications 
L * W * H (mm)
2600*1400*1400 2300×1250×1900 3500×1900×1800
Working pressure -60Kpa -60Kpa -60Kpa
Adjustable range of working temperature 50ºC ±3ºC 50ºC ±3ºC 50ºC ±3ºC
Working humidity 45%‐75% 45%‐75% 45%‐75%
Sterilization time 0-99 hours
adjustable
0-99 hours adjustable 0-99 hours adjustable
Material of disinfection room 304 anticorrosive
stainless steel
304 anticorrosive 
stainless steel
304 anticorrosive 
stainless steel
 
Model HTY-8cube HTY-10cube HTY-20cube
Disinfection mode Low temperature Low temperature Low temperature
Rated power 18KW 22KW 22KW
Liner specifications 
L * W* H (mm)
5200*1200*1300 4200*1400*1700 5000*1800*2250
Working pressure 0--60Kpa 0--60Kpa 0--60Kpa
Adjustable working 
temperature
50ºC ±3ºC 50ºC ±3ºC 50ºC ±3ºC
Working humidity 45%‐75% 45%‐75% 45%‐75%
Sterilization time 0-99 hours adjustable 0-99 hours adjustable 0-99 hours adjustable
Material of disinfection room 304 anticorrosive stainless steel 304 anticorrosive stainless steel 304 anticorrosive stainless steel

Technical characteristics and advantages of ethylene oxide sterilizer
HTY series ethylene oxide sterilizer is a special equipment for low-temperature fumigation and sterilization of articles sealed in the sterilization room under a certain temperature, pressure, humidity and a certain action time with the mixture of pure ethylene oxide and ethylene oxide. Ethylene oxide gas is a very active chemical disinfectant, which can not only achieve broad-spectrum sterilization, but also achieve a reliable sterilization effect.

Advantages
Simple operation: one-button operation, microcomputer control, simple and convenient, digital display of sterilization process.
Print records: Record and print sterilization information for sterilization process, which is convenient for verification and archiving.
Filtration system: The air inlet is equipped with a filtration system, which can effectively filter out germs and microorganisms and avoid secondary pollution during exhaustion.
Application: Hysteroscopy, Laparoscopy, Laryngoscope, Probe, Rigid Endoscope, Hose Endoscope, Ophthalmic Lens, Fiber Optic Cable, Cranial Pressure Sensor, Cold Therapy Probe, Prostatectomy Device, Esophageal Dilator, Electrocautery Devices, defibrillation electrodes, laser head metal, glass, silicone, Chinese medicine and western medicine, human implants, masks, DNA, etc.

High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
Transportation Packing 
High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection
Company Strength (Real scene of processing workshop )

High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection

International Exchange (Inspections and cooperation with domestic and foreign leaders)

High Efficiency Ethylene Oxide Sterilizer Used for Hysteroscopy, Laparoscopy, Laryngoscope Disinfection

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier