Customization: | Available |
---|---|
Theory: | Pneumatic |
Type: | Pressure Steam Sterilization Equipments |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Ethylene Oxide Sterilizer Machine Manufacturer
Product forms | HTAJ3 manual door cabinet |
Power source | AC380V,50Hz |
Sterilizer size | (Length × width × height): 2600×1400×1400mm |
Sterilizer volume | 6m³ |
Sterilizer interior material | 304 Anticorrosive stainless steel |
Outer carton material | Carbon steel |
Temperature during sterilization | 50ºC ±3ºC |
Working pressure | -60kpa |
Maximum anti-stress value | -150kpa |
Humidity during sterilization | 45%-75% |
Pressure sensor | The built-in pressure sensor automatically detects the pressure inside the cavity to ensure that the pressure in the cavity is accurate and effective. |
Ethylene oxide sterilization concentration | 1g/L Adjustable |
Leakage rate of sterilization chamber | The leakage rate is measured under the conditions of no-load and constant temperature in the sterilization chamber, the test pressure is -50kPa, and the measurement time is 1h. The average leakage rate within the measurement time is ≤0.16kPa / min. |
Sterilization time | 0-99 hours Adjustable |
Vacuum speed | 15-25 minutes to -60kpa |
Air replacement | Automatic ventilation, ventilation times and interval time can be set freely |
Automatic control system | One-key start to end, the whole process of automatic completion with printing records |
Display status | Display temperature, humidity, pressure, sterilization time, residual gas treatment time, frequency |
Printer |
Record and print the sterilization information of the whole process for verification. |
Humidity sensor | The built-in humidity sensor automatically detects the humidity in the cavity to ensure that the humidity in the cavity is not less than 45% RH. |
Residual gas treatment device | The removal rate of the filter with a particle diameter ≥ 0.3 μm is not less than 99.5%. |
Temperature sensor | The built-in temperature sensor automatically detects the temperature in the cavity to ensure that the temperature in the cavity is maintained within an accurate range of 50 ° C ± 3 ° C. |
Humidification system | Pulse humidification under vacuum to ensure that the humidity in the cavity is uniform and controllable; the humidity in the sterilization chamber should be controlled within the range of relative humidity 45% -80%; |
alarm system | High temperature alarm system, ultra-low pressure alarm system; When the sterilization temperature of sterilization chamber exceeds 59ºC, the alarm shall be audible. |
Vacuum rate | Under no-load condition, the time for the sterilization cabinet to vacuum from atmospheric pressure to -60kpa should be ≤30min. |
Vacuum system | The use of oil-free vacuum pump, simple and convenient, fast vacuum rate, long service life. |
Multiple protection functions | With over - pressure and over - temperature protection function, more safe and reliable. |
Heating system | Adopt explosion-proof electric heating device, more convenient and fast |
The Group relies on aggregating professionals in the field of medical equipment, concentrated technical forces to invest in research and development, and rapidly rises in the medical field. With great investment in research and development and innovation, the company has achieved a series of results in the related fields of ethylene oxide sterilizers. Combined with the 5G intelligent AI platform to realize the intelligent operation of the equipment, the simplicity, safety, and sterilization effect exceed the customer's requirements. We always treat our customers with a high standard and a responsible attitude. The corporate philosophy of being a person first, and then acting, has laid a solid foundation for the group company to deepen its cultivation in the medical device industry.